Using the design methodology adopted in the cop section 8 for roof drainage factors are applied to catchment pitch and cross sectional area.
Internal gutter design nz.
Made form galvsteel zincalume colorsteel.
A gutter at the internal intersection of two sloping planes of roof cladding where the roof pitch is 12 or greater.
Clause b2 durability requires 15 year minimum durability.
A valley gutter is defined in the cop as.
Nz s leading provider of steel roofing guttering products for residential commercial customers.
Internal gutter construction gutter construction varied from a simple shallow trough or v like a valley detail to a tapered valley laid over firred framing to give a fall figures 5 and 6.
All dimond branches can fold gutter shapes with swages patterns to be confirmed at time of order 1 gutter bracket material and thickness.
Internal gutters also known as box gutters are seen as an easy solution to the collection and disposal of roof water.
Back bu556 internal gutter design.
This bulletin outlines the requirements of e1 as1 and e2 as1 and gives design parameters to minimise the risk.
Good internal gutter design includes.
E2 as1 specifies no end laps for membrane lined internal gutters and that metal gutter laps are welded.
Show what documents this resource is cited by show what documents this resource cites.
This bulletin outlines the requirements of e1 as1 and e2 as1 and gives design parameters to minimise the risk of problems.
Bu556 internal gutter design this document is not cited by any other resources.
Constructing gutters that are large enough to cope with the maximum rainfall intensity for the region lining the gutter with a continuous impermeable material providing a good fall to outlets.
Design for a 10 minute rainfall intensity for the location with a recommended minimum design intensity of 200 mm hour rainfall intensity is for a storm with a 10 probability of occurring annually.
Often the outlet to the valley gutter discharged over a small portion of roof before being contained by the eaves gutter figure 7.
Because of their design and construction small defects of installation or blocked drainpipes can cause overflows into the.
There are three new zealand building code clauses that must be applied to internal gutter design.
Clause e1 surface water requires that construction protects people and other property from the adverse effects of surface water.
Internal galvanised 1 15mm external hot dipped galvanised 3mm x 32mm aluminium 5mm x 30mm brass 3mm x 30mm stainless steel 3mm x 30mm.